Skip to main content
BSACL Certification

Plant & Equipment

Equipment Inspection

Condition and compliance inspection of plant and equipment against its specification and the requirements applying to its use — distinct from statutory thorough examination.

At a glance

Availability
Being confirmed — enquire first
Assessed against
Specification and applicable requirements
Statutory examination
Not offered — see notice
Output
Condition report with evidence

We do not carry out statutory thorough examinations

Our inspection service lines, coverage, and the regions we can attend are still being confirmed. Treat this page as a description of intended services rather than a commitment, and contact us before relying on it for a project. Beyond that: in the UK, thorough examination of lifting equipment under LOLER, examination under a written scheme for pressure systems under PSSR, and inspection of work equipment under PUWER are duties that must be discharged by a competent person, and they carry specific legal consequences. We do not offer statutory thorough examination, and a condition report from us does not satisfy those duties or replace the required examination. If that is what you need, appoint a competent person for it — and we will say so plainly rather than let you assume otherwise.

About this service

Equipment Inspection

Equipment inspection in the sense meant here is a condition and compliance assessment: what state is this plant in, does it match what it is supposed to be, and does it meet the requirements applying to its use? It is commonly commissioned when buying used plant, accepting equipment onto a site, resolving a dispute, or building a picture of an estate.

It sits alongside, and does not replace, the statutory regime. UK law imposes specific duties for certain equipment — thorough examination of lifting equipment and accessories under LOLER, examination against a written scheme for pressure systems under PSSR, and inspection of work equipment under PUWER. Those are competent-person activities with defined intervals and legal consequences, and they are a different service from the one described on this page.

Who it is for

Anyone taking on equipment, or needing an independent view of its state.

  • Buyers acquiring used plant or machinery
  • Sites accepting equipment from a contractor or hirer
  • Organisations building a condition picture across an estate
  • Parties in a dispute needing an independent condition record

Scope of work

What an inspection covers

Scoped to the equipment and the reason for looking at it.

  • Identification and specification

    Whether the equipment is what it is described as — make, model, serial, rating, and configuration against the documentation.

  • Physical condition

    Visible condition, wear, damage, corrosion, and modifications, recorded with photographic evidence.

  • Safety features

    Whether guarding, interlocks, emergency stops, and protective devices are present, intact, and appear functional.

  • Markings and documentation

    Rating plates, markings, manuals, and any declarations or records that should accompany the equipment.

  • Examination records

    Whether the statutory examination and maintenance history exists and is current — we check that it is there, not perform it.

  • Functional observation

    Where it can be operated safely and that is within scope, observation of the equipment running.

How it runs

How an inspection runs

Scope defined tightly, because the boundary matters here.

  1. Purpose and scope

    What the equipment is, why it is being inspected, and specifically whether a statutory examination is what you actually need.

  2. Criteria agreed

    The specification and requirements the equipment will be assessed against, in writing.

  3. Site attendance

    Inspection on site, with access, isolation, and safe operation arranged by the site as required.

  4. Condition recorded

    Findings documented with photographic evidence and, where relevant, measurement.

  5. Report issued

    A written condition report stating what was assessed, what was found, and explicitly what was outside the scope.

Scope

Scope boundaries

The most important boundary on this page is the statutory one.

What is included

  • Condition and compliance assessment against the agreed criteria
  • Findings recorded with photographic evidence
  • A check that statutory examination records exist and are current
  • A written report suitable for your own records

What is not included

  • Statutory thorough examination under LOLER, PSSR, or PUWER
  • Acting as the competent person for any statutory duty
  • Certification of the equipment or a conformity marking
  • Repair, maintenance, or modification of the equipment

Before you start

Common questions

Is this a LOLER thorough examination?

No, and the distinction is legally important. Thorough examination under LOLER must be carried out by a competent person, at intervals commonly of six months for lifting accessories and equipment used to lift people and twelve months for other lifting equipment, or in accordance with a written scheme of examination. We do not provide that service. A condition report from us does not discharge the duty.

What is a written scheme of examination?

Under the Pressure Systems Safety Regulations, certain pressure systems require a written scheme of examination drawn up by a competent person, covering the vessels and protective devices and setting the examination intervals. Equipment can also be examined under a written scheme in place of the standard LOLER intervals where a risk assessment justifies it.

Who counts as a competent person?

Someone with sufficient practical and theoretical knowledge and experience of the equipment to detect defects and judge their significance, and sufficiently independent and impartial to report without pressure. Guidance is clear that it should not be the person who carries out routine maintenance on the same equipment.

Can you tell us whether the equipment is safe to use?

We report the condition we observed against the agreed criteria. A decision to put equipment into service rests with the duty holder and, where the law requires it, on a statutory examination by a competent person — not on a condition report.